⚡ Power your professional edge with Ampinvt’s pure sine wave mastery!
The Ampinvt 1200W Pure Sine Wave Inverter is a high-performance, multi-functional power solution combining inverter, battery charger, and auto-transfer switch. Designed for professional-grade reliability, it supports multiple battery types with adjustable charging currents and five intelligent working modes. Its advanced protections and over 90% efficiency ensure stable, clean power output ideal for sensitive electronics and backup power needs.






| Antenna Location | Off-grid use, Backup power source |
| Asin | B0989XPZ48 |
| Box Contents | AC Charger |
| Brand Name | AMPINVT |
| Colour | Silver |
| Customer Reviews | 4.3 4.3 out of 5 stars (192) 4.3 out of 5 stars |
| Display Type | LED |
| Electrical Output Waveform | Pure Sine Wave |
| Energy Specifications Standard | UL, ETL |
| Frequency | 0.5 Hz |
| Input Voltage | 12 Volts |
| Inverter Capacity Volt Amp | 1200 |
| Item Dimensions L X W X H | 25.4L x 13W x 31H centimetres |
| Item Weight | 8.62 kg |
| Manufacturer | Top one power |
| Manufacturer Part Number | HT-1200W12V |
| Model Name | HT |
| Model Number | HT-1200W12V |
| Number Of Items | 57 |
| Number Of Outlets | 1 |
| Output Power | 1200 Watts |
| Output Voltage | 110 |
| Peak Output Power Watts | 3600 |
| Power Source | Battery Powered |
| Standby Power Shutoff | 90% |
| Unit Count | 1.0 count |
| Voltage | 12 Volts |
| Wattage | 1200 watts |
User
Very good for a backup UPS system, but not for an RV
I purchased this to upgrade the modified sine wave inverter/charger in my RV. Its power output was a bit higher than my current system, it can be set for LiFePO4 batteries, and of course it provides a pure sine wave output (did you know that a "modified sine wave" will destroy the speed controller in a KitchenAid mixer? Well, now you do...). Unfortunately, it is not a good fit for this application, because the maximum battery charging current (the "converter function" in RV parlance) is only 15 amps.This means that after boondocking for a couple of days, or even while plugged in at an RV park, the house batteries will take a long time to fully recharge, and if there's much load in the coach, they'll never recharge and could likely discharge further. For this usage, the charger/converter really needs to be able to source well over 30 amps - 50 amps is way better.For a stationary UPS setup though, this unit is fine. The recharge rate is not so critical in this application, because the batteries aren't supplying the load while on city power. Also, the changeover from city to UPS power is extremely quick - less than a single cycle (17 msec). There's no drop-out at all during switch-over, just a bit of a glitch in the waveform. The fan does run at slow speed all the time, and it's not silent, but that's not a problem for me because it's installed in an equipment room with lots of other fans running too.I haven't run the unit at full load, so I don't know if complaints in some other reviews about not achieving full rated power are valid. It would be easily possible for some of those issues to be caused by drooping incoming 12-volt power (loose connections, too-small wire, or inadequate/discharged batteries). In my (new, re-purposed) application of an electronic equipment room backup, when paired with a 300 Ah LiFePO4 battery, it works great.A couple of other reasons the unit was able to hold onto its five-star rating: The display shows genuinely useful information - AC input voltage, battery voltage, load current. It also makes a guess about the battery state-of-charge, but it's usually wrong...It's also quite efficient. Its power draw in inverter mode when completely unloaded is well under an amp, which is certainly OK for sine wave inverters. (I have another one that draws 3 amps - 36 watts - continuously, even with no load.) Of that idle current draw, I bet at least half goes to keeping the fan running, which could have been optimized.The unit has another mode in which it powers up briefly every 10 seconds to see if there's an AC load, and if not, powers back down to very low draw. This could be useful in some applications where the load is constant when switched on, but may be off for prolonged periods (like a sump pump), and would wring a much longer life out of the backup battery bank. However, for more general ad-hoc applications, such as a cabin backup, the regular "AC-priority" mode, or possibly the "unattended mode", would be better.The "unattended mode" acts just like AC priority mode in that city grid power is used if available, or inverter power if not. In this mode, however, if the batteries get too low it goes to a very low power mode, then returns to inverter mode when the batteries are recharged some (via solar, for example). Just about perfect for a remote cabin with flakey city power and some solar panels.The unit appears to be conservatively designed and well built, and well laid out for convenient wall installation. There's an RS-485 port that should be useful, but I was unable to get any information about its communication protocol, so ... not so useful after all. All told, I'm quite happy with the unit in its UPS application, and I may end up moving it to a little cabin/pub I'm building in a remote corner of my property... ;-)
User
Hay fallas en el inversor incluso con poca carga lo devolvi
hay fallas incluso con poca carga es in inverter caro y de baja calidad
User
Great UPS alternative!
>2 years of uptime on multiple servers in my little home datacenter. Thanks to this little guy. Still going strong. I just acquired a few GPUs. Measuring about 1000 W at the wall. The fan will spin up, but the Ampinvt shrugs off the load. The load indicator never goes over 85. I do believe it beeped at me when I was doing inference at full tilt.When the fan speed fluctuates at lower load, my wife says it sounds like “crying computers”. But it’s not keeping anybody awake in the next room.The charging is a bit limited - basic voltage control, but no granular control over charge/soak cycles like my victron. But the Victron was 2x the price and lacks an inverter.The value is hard to beat: I came back two years later to write this review, which is speaks to the quality. I might just pick up another one.
User
Works great as emergency power backup
I bought the 1200W unit to use as an emergency power backup for when our house loses power in snowstorms. I primarily have it powering a blower on a gas fireplace and some LED lights, and one standby outlet in case we need to plug in a phone or something.In light of other reviews, the very first thing I did was wire it up and test the AC outlet on it to make sure it was wired properly. It was, so hopefully they've fixed the minor assembly error. While I was at it I tested the rest of the terminals and they all were correct too.As others have said, the unit itself is fairly heavy and the terminal screws are tough to get to when mounted, so best to connect the cables to it first and then mount it where you intend to put it. I made sure to attach it directly to studs, there's no way drywall anchors would safely hold this amount of weight.I paired it with a 100Ah LiFePO4, set the charging voltage to the recommended voltage for the battery, and run it in "AC Priority" mode and it works seamlessly. The display does incorrectly show the battery at "70%" when it switches to DC power, since the battery voltage is ~1V lower under load/rest than it is while charging. But I consider that to be par for the course for these types of things. I let it run my blower and lights for 3 hours and the charge hadn't dropped 1% yet, so it's working fine.The fan does indeed run all the time when the unit is on. I have it mounted in my heated garage with a bunch of other equipment so that's not an issue for me.I experimented with running it in "ECO Mode" but it wants a larger current draw than I'm providing at idle in order for the inverter to run. If you don't draw enough power in ECO Mode, then it cycles on and off in about 4 second intervals looking for a load. That struck me as suboptimal so I'm just going to use it in AC Priority mode like a typical UPS.The manual is a little unclear on this, but the setting for "Battery Charge Current" is settable in 20% intervals up to "100%", with no indication of what that current is. It seems 100% is 15A @ ~14VDC, so it adds about 2A to the 120VAC load it's drawing from the line circuit when it is charging the battery. Take that into account for your AC load capacity feeding the unit.Overall, exactly what I needed and I'm happy with it.
User
Perfect sump pump power outage backup .
This item works perfect to keep my sump pump running if the power goes out. Good build quality, easy hookup. Getting it setup (programmed) is a bit tricky. I have not figured out if I can set a minimum voltage for cut-off and the cooling fan runs all the time even when the unit is not working as a passthrough when shore power is on or when its using the battery. When its running an item the fan speeds up even more. It is loud enough I can hear it upstairs. I think the fan should only run when the unit is actually powering an appliance. I tested it by turning off the breaker feeding it while the sump pump was running. Instantly switched to battery power. When grid power is turned back on it starts re-charging the battery. It keeps the PowerQueen 100ah battery topped off . Once setup, there is nothing more you need to do. Been using this for a few months now with zero problems. Peace of mind when im away from home.